Unlined

CONCRETE JACKING PIPE RANGE – DN300 -DN3000

Standard: AS/NZS 4058:2007   Precast concrete pipes (pressure and non-pressure)

BILCON AUSTRALIA CONCRETE JACKING PIPE TECHNICAL INFORMATION

Internal Diameter (mm) External Diameter (mm) Wall Thickness (mm) Effective Length (mm) Packer Thickness (mm) Steel Collar Thickness (mm) Weight (kg) Max Jacking Load2 (tonnes) Collar Type
300 450 75 2000 12 2 430 75 F
375 584 104.5 2000 12 2 760 149 F
400 650 125 2000 12 2 990 204 F
450 650 100 2000 12 2 830 163 F
500 675 87.5 2000 12 2 775 147 F
600 775 87.5 2000 12 2 910 173 F
700 875 87.5 2000 12 2 1,040 199 F
800 1052 126 2000 12 4 1,760 462 F
900 1140 120 20001 18 4 1,850 481 F / B
1000 1250 125 20001 18 4 2,125 558 F / B
1050 1300 125 20001 18 4 2,220 583 F / B
1200 1470 135 20001 18 4 2,720 727 F / B
1350 1600 125 20001 18 6 2,780 734 B
1500 1780 140 20001 18 6 3,470 935 B
1650 1950 150 20001 18 6 4,080 1,113 B
1800 2170 185 20001 18 6 5,540 1,559 B
2000 2410 205 2750 18 8 9,890 1,944 B
2100 2470 185 2750 18 8 9,245 1,797 B
2400 2810 205 2750 18 10 11,680 2,300 B
2500 3000 250 2750 18 10 15,035 3,020 B
3000 3500 250 2750 18 10 17,770 3,573 B
  1. Also available in effective lengths of 2750mm
  2. Max Jacking Loads calculated in accordance with BS EN 1916:2002 Annex B, with total safety factor of 3.33